| Vin = 24 V Vout = 35 V Viso = 50 kV Pmax = 90 W APPLICATIONS - Auxiliary power supply for high voltage power semiconductors (IGCTs from ABB) - DC and AC (70 kHz) Output voltage, Connector on the top of the device - Serially connected high voltage power semiconductors |
| PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT |
| Input Voltage Vin | DC voltage | 22 | 24 | 27 | V |
| Output Voltage Vout | DC voltage, Load: 2 W to 80 W | 28 | 35 | 40 | V |
| Max. Output Power Pmax | Vin = 24V | 80 | 90 |
| W |
| Input Power | Pout = 80 W, Vin = 24V |
| 95 | 98 | W |
| Insulation Voltage output to ground Viso | 50 Hz AC voltage, 30 s, without Partial Discharge (< 10pC) | 47 | 50 |
| kV |
| Insulation Capacitance | output to ground |
| 30 |
| pF |
| Max. dv/dt (Insulation) | ground connection at base plate |
|
| 25 | kV/µs |
| Short Circuit Time | output shortened | 1 |
|
| min |
| Ambient temperature | max. load of 80W | -20 | 50 | °C | |
| Storage temperature | -20 | 70 | °C |
| Length Input Line | 0,9 -1,1 m |
| Colours Input Connection | brown = input voltage + blue = input voltage - green / yellow = ground |
| Output Connector Phoenix MSTB 2.5 -5.08 4 pol | 1 = AC output voltage ~ 2 = DC output voltage - 3 = DC output voltage + 4 = AC output voltage ~ |
INSTALLATION INSTRUCTIONS It is important to make a low inductive ground connection. It is recommended to make a connection between the negative input voltage and ground. The environment must be clean and dry. Excessive temperature should be avoided. | DIMENSIONS![]() |
| PARAMETER | TYP | UNIT |
| Height | 155 | mm |
| Weight | 2500 | g |
IMPORTANT NOTICE ALL DATAS ARE PRELIMINARY Siebel & Scholl GmbH reserves the right to change specifications without notice. Siebel & Scholl GmbH makes no warranty regarding the suitability of this product for any particular purpose. Mounting only by technical experts.