- About company
- |
- Products
- |
- News
- |
- Applications
- |
- Contacts
|
Technical data
Output current shielded cable | NCS165T-10AF | NCS165T-20AF | - | |||
Output voltage shielded cable | - | NCS165T-10VF | - | NCS165T-20VF | ||
| Nominal primary current |
| A peak | 10000 | 10000 | 20000 | 20000 |
| Measuring range |
| A peak | 30000 | 30000 | 40000 | 40000 |
| Not measured overload | 1s/h | A peak | 200000 | 200000 | 200000 | 200000 |
| Secondary current IS1 at IPN |
| mA peak | ±20 | - | ±20 | - |
| Secondary current IS2 at IPMAX |
| mA peak | ±20 | - | ±20 | - |
| Residuel current IS10 | @+25°C | µA | <±250 | - | <±250 | - |
| Residuel current IS20 | @+25°C | µA | <±180 | - | <±180 | - |
| Thermal drift coefficent (outputs IS1, IS2) |
| µA/°C | <±4 | - | <±4 | - |
| Measuring resistance (outputs IS1, IS2) |
| Ω | 0 ... 350 | - | 0 ... 350 | - |
| Secondary voltage VS1 at IPN | @+25°C | V peak | - | ±10 | - | ±10 |
| Secondary voltage VS2 at IPMAX | @+25°C | V peak | - | ±10 | - | ±10 |
| Residuel voltage VS10 |
| mV | - | <±100 | - | <±100 |
| Residuel voltage VS20 |
| mV | - | <±50 | - | <±50 |
| Thermal drift coefficent (outputs VS1, VS2) |
| mV/°C | - | <±2 | - | <±2 |
| Measuring resistance (outputs VS1, VS2) |
| Ω | - | 10000 ... ∞ | - | 10000 ... ∞ |
| Rms accuracy 50Hz (without offset)1 at IPN | @+25°C | % | ≤±1 | ≤ ±1 | ≤±1 | ≤ ±1 |
| Rms accuracy 50Hz (without offset)1 at IPMAX | @+25°C | % | ≤±3 | ≤±3 | ≤±3 | ≤±3 |
| Gain thermal drift | -25°C ... +85°C | %/°C | ≤0.03 | ≤0.03 | ≤0.03 | ≤0.03 |
| Gain thermal drift | -40°C ... -25°C | %/°C | ≤0.1 | ≤0.1 | ≤0.1 | ≤0.1 |
| Linearity (typical) |
| % | ±0.5 | ±0.5 | ±0.5 | ±0.5 |
| Delay time (typical) |
| µs | ≤3 | ≤3 | ≤3 | ≤3 |
| di/dt correctly followed |
| A / µs | ≤100 | ≤100 | ≤100 | ≤100 |
| Bandwidth | @-1dB | kHz | 0 ... 10 | 0 ... 10 | 0 ... 10 | 0 ... 10 |
| No load consumption current (IA0+) | @-40°C | mA | ≤210 | ≤210 | ≤210 | ≤210 |
| No load consumption current (IA0-) |
| mA | ≤35 | ≤35 | ≤35 | ≤35 |
| Dielectric strength Primary/Secondary | 50 Hz, 1 min | kV r.m.s. | 20 | 20 | 20 | 20 |
| Supply voltage | ±25% | V d.c. | ±24 | ±24 | ±24 | ±24 |
| Mass |
| Kg | 1.2 | 1.2 | 1.2 | 1.2 |
| Operating temperature |
| °C | -40 ... +85 | -40 ... +85 | -40 ... +85 | -40 ... +85 |
| Storage/startup temperature |
| °C | -50 ... +90 | -50 ... +90 | -50 ... +90 | -50 ... +90 |
| Accessories and options Flanges (or right angle brackets)For installation of the flanges, please refer to the mounting instructions ref. 1SBC146005M1701 ● lange kit NCS125T: ABB order code: 1SBT200000R2001 For other options please contact us. | Conformity EN50155 EN50121-5, EN50123-1, EN50124-1 |